I-7188E2D-MTCP # Device Server/Gateway/Modbus/TCP/IP/RS-232/RS-485/Ethernet/LED, ICP DAS
I-7188E2D-MTCP # I-7188E2 with default Modbus/TCP firmware, LED
Features of default Modbus firmware |
When you buy an I-7188E2 -MTCP controller, it already has the default Modbus firmware installed in Flash memory. The default firmware has the follows features:
-
Supports VxComm technique for every COM port of controllers If serial devices don't support Modbus/RTU, you can still access these devices. But need to install VxComm driver on host PCs and assign a COM port number to link to the remote COM port (of I-7188E2 -MTCP). After that, serial clients can access these remote serial devices via standard RS-232 functions.
-
- Firmware modifiable
We provide the Modbus SDK allowing users to develop their custom Modbus firmware.
|
Modbus SDK ( in C language ) |
If the default firmware doesn't totally suit your requirement. You can use Modbus SDK to modify the default firmware to add extra functions. The Modbus SDK has below features:
|
|
-
Supports extra user-defined command protocol (TCP/IP) Modbus/TCP protocol supports 2 basic data format (bit and 2-byte integer). It means if clients (or called masters) don't support Modbus/TCP or you need other format data (for example: string of floating value), I-7188E2 (with default firmware) cannot communicate with them. Using this feature, you can develop your special command protocol to transfer any format of data.
-
Register based programming method (easy to use) Modbus library supports 4 internal register tables (iMemory_AI, iMemory_AO, iMemory_DI, iMemory_DO), you can use these to store specific information. When Modbus/TCP clients request to I-7188E2-MTCP, Modbus kernel will response information from these 4 tables.
- Provides user-defined registers
The 4 internal register tables are all open to users. You need to assign these tables by yourself.
-
Can link to Modbus/TCP slave devices By using function ModbusTCP_Master2Slave(declared in MBTCP_7E.h),the I-7188E2-MTCP can link 8 max . Modbus/TCP device.
-
Can link to Modbus/RTU slave devices By using function ModbusMaster2Slave (declared in MBTCP_7E.h), Modbus/RTU devices can be easily integrated to internal registers of I-7188E2-MTCP. An I-7188E2-MTCP polling every Modbus/RTU devices and put every necessary information to internal registers. Clients only ask the I-7188E2-MTCP to get all information of Modbus/RTU devices. That reduces loading of Clients.
-
Can link to non-Modbus/RTU serial devices Some serial devices don't support Modbus/RTU. We provide functions to let I-7188E2 -MTCP access serial devices. You can put information to internal registers of it. Thus, the non-Modbus serial devices can also support Modbus/TCP.
-
Xserver SDK compatible Modbus SDK is based on Xserver SDK. To lear more programming skills, you can refer demos of Xserver. To get information of demos of Xserver, please refer to CD:\Napdso\7188e\TCP\Xserver\Xserver.htm
|
Modbus Utility |
We provide Modbus tools for Windows 98/SE/NT/2K/XP, it includes:
- Modbus Utility
- On-line configuration via Ethernet
- On-line help
- Automatically generate register mapping tables
- Configuration export/imp
- MBRTU
Modbus/RTU client (with source code in VB6) to diagnostic Modbus/RTU slave devices.
- MBTCP
Modbus/TCP client (with source code in VB6) to diagnostic Modbus/TCP slave devices.
|
- Basic application 1: protocol converter
An I-7188E2 -MTCP runs a default firmware to become a single Modbus/TCP to multi-Modbus/RTU converter. You can simply use the Modbus Utility to configure the device and then set connection between SCADA , HMI software and the I-7188E2-MTCP. |
|
- Basic application 2: protocol converter with VxComm technique
An I-7188E2 -MTCP is also be able to link to serial devices that don't support Modbus/RTU. To use this function, you will need to install VxComm driver on host PCs. After installation, you will be able to access the remote COM ports via the standard serial driver. |
|
- Advanced application 1: Modbus/TCP controller
Using the Modbus SDK, users can develop their own custom Modbus firmware, allowing extra functions, integration of serial devices and a Xboard to the Modbus/TCP kernel. Thus an I-7188E2 can become a powerful controller. |
|
- Advanced application 2: Modbus/TCP controller with VxComm technique
When an I-7188E2 -MTCP links same hardware devices as Advanced application 1 link to, if any devices connected to certain COM ports are not integrated into your custom firmware, you are still able to access the COM ports via the standard serial driver. In order to do this, you must install the VxComm driver on the host PCs |
CPU |
CPU |
80188, 40MHz or compatible |
SRAM |
384K bytes
|
Flash Memory |
512K bytes |
EEPROM |
2K Bytes |
Built-in Watchdog Timer |
Yes |
Communication Interface |
COM1 |
RS-232 (TXD, RXD, RTS, CTS, GND) |
COM2 |
RS-485 (D2+, D2-) |
Ethernet Port |
10BASE-T NE2000 compatible Ethernet Controller |
COM Port Formats |
Data bit |
7, 8 |
Parity |
Even, Odd, None |
Stop bit |
1 |
LED Display |
5-Digit 7 Segment LED Display |
Yes (for I-7188E2D-MTCP only) |
System LED Indicator |
Yes |
Dimensions |
I-7188E2(D)-MTCP |
123mm x 72mm x 33mm |
Operating Environment |
Operating Temperature |
-25°C to +75°C |
Storage Temperature |
-40°C to +80°C |
Power |
Protection |
Power reverse polarity protection |
Required Supply Voltage |
+10 to +30V/DC (non-regulated) |
Power consumption |
2W for I-7188E2-MTCP 3W for I-7188E2D-MTCP |
I-7188E2-MTCP |
I-7188E2 with default Modbus/TCP firmware |
I-7188E2D-MTCP |
I-7188E2D with default Modbus/TCP firmware |
I-7188E2D-MTCP-G |
I-7188E2D with default Modbus/TCP firmware (Gray Cover) |
s!nus-elektrotechnikai bt.
Industrial IT & Automation
|
25 éves jubileum / 25 th Anniversary
www.s-e.hu # www. icpdas.hu
Email: info@s-e.hu # Tel: 96/525530 # Fax: 96/525531 # Mobil: 30/9464608
|
RS-232, RS-422, RS-485 konverterek, Ethernet konverterek, RS-485 I/O, Modus I/O, Soros-Ethernet konverterek, USB I/O, Ethernet I/O, Profibus, M-bus, Rádió modem, Ethernet switch, CAN, CANopen, DeviceNet, Profinet, HART, BACnet, EtherCAT, EtherNet/IP, Wireless MBus, DALI, ZigBee, LoRaWan, SIGFOX, IoT, TouchPAD Fogyasztásmérés és leolvasás USB konverter ICP DAS HUNGARY
RS-232 - WiFi konverter, RS-485 - WiFi konverter,
ICP CON konverter USR IOT konverter
Sinus-Elektrotechnikai Bt. ICP DAS HUNGARY
RS-232 konverter, RS-422 konverter, RS-485 konverter, RS-485 repeater, USB konverter, Soros Ethernet konverter, RS-232 Ethernet konverter, RS-422 Ethernet konverter, RS-485 Ethernet konverter, Ipari Ethernet switch, Managed DIN switch, PAC, PLC, HMI, Programozó kábel, Ipari monitor, Ipari éritőképernyős monitor, Ipari PC, Ipari laptop, Ipari tablet, Ipari panel PC, Barebone PC, Mini ITX PC, RS-485 I/O, Profibus I/O modul, Profibus gateway, Profibus konverter, Profibus átjáró, Profibus csatlakozó, Modbus I/O, Ethernet I/O, Modbus gateway, CAN konverter, CAN I/O, CANopen konverter és I/O, DeviceNet konverter és I/O, Hart konverter, Ethernet/IP modul és konverter, BACnet/IP modul és konverter, PROFINET konverter, I/O modul, EtherCAT modul, M-Bus modul, konverter, DALi modul, DALI konverter, PLC programozó kábel, Siemens programozó kábel, WiFi I/O, GSM modem, GPRS modem, SMS küldő, ZigBee konverter, ZigBee I/O, Bluetooth modul, LoRaWAN modul, SIGFOX Modul, IIoT MQTT modul, Média konverter, Touch Pad, Optikai leolvasófej, Analóg, Digitális, Soros PCI kártyák, Épület automatizálás, Ipari tápegység, Ipari kamera, MachineVision, Fogyasztásmérés és elemzés, Földrengés előjelzés, Adatgyűjtés eszközei, Rezgés elemzés, konverter és repeater, Profibus kábel, Profibus csatlakozó, Soros RS-232 RS-485 WiFi konverter, Ipari Gigabit Ethernet switch, WiFi i/o modul, IEC 1107 mérőleolvasás, Optikai leolvasó fej ICP DAS, ICPDAS, ICP CON, MOXA, ADEUNIS, USR IOT, IEI, B+B SmartWorx, ELKO EP, EXSYS, LILLIPUT, STARTECH, PATTON
All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorisation by any rights holder.
© 2018-2022 Sinus-Elektrotechnikai Bt. Minden jog fenntartva.
A műszaki adatok és információk előzetes értesítés nélkül megváltozhatnak.