Termék részletek


I-7188EXD-MTCP # Controller/Gateway/MiniOS7/C nyelv/Modbus TCP/Ethernet/RS-232/RS-485/512KB/LED, ICP DAS

Rendelésre 4-10 munkanap
Rendelésre 10-15 munkanap
Raktárkészlet: NINCS
I-7188EXD-MTCP # Controller/Gateway/MiniOS7/C nyelv/Modbus TCP/Ethernet/RS-232/RS-485/512KB/LED, ICP DAS
  • I-7188EXD-MTCP # Controller/Gateway/MiniOS7/C nyelv/Modbus TCP/Ethernet/RS-232/RS-485/512KB/LED, ICP DAS
85 209 Ft 108 215 Ft
  • I-7188EXD-MTCP CR # Controller/Gateway/MiniOS7/C nyelv/Modbus TCP/Ethernet/RS-232/RS-485/512KB/LED, ICP DAS
  • I-7188EXD-MTCP CR # I-7188EX with default Modbus/TCP firmware, LED (RoHS)
  • Kontroller, gateway
  • Modbus TCP - Modbus RTU konverter, átjáró
  • Nem Modbus eszközök Modbusra csatlakoztatása
  • Ethernet, RS-232, RS-485 port
  • DIN sínre rögzíthető

 

  • I-7188EXD-MTCP CR # Controller/Gateway/MiniOS7/C nyelv/Modbus TCP/Ethernet/RS-232/RS-485/512KB/LED, ICP DAS
    I-7188EXD-MTCP CR # I-7188EX with default Modbus/TCP firmware, LED (RoHS)

     

    Features of default Modbus firmware

    When you buy an I-7188E -MTCP controller, it already has the default Modbus firmware installed in Flash memory. The default firmware has the follows features:

    • Converters single Modbus/TCP to multi Modbus/RTU 
      The I-7188E -MTCP is a Modbus/TCP gateway. It can easily upgrade many Modbus/RTU devices to have Ethernet communication ability.
    • Supports VxComm technique for every COM port of controllers 
      If serial devices don't support Modbus/RTU, you can still access these devices. But need to install VxComm driver on host PCs and assign a COM port number to link to the remote COM port (of I-7188E -MTCP). After that, serial clients can access these remote serial devices via standard RS-232 functions.
    • Allowed multi-client (or master) access simultaneously 
      Different I-7188E -MTCP controller supports different client numbers connect to. Please refer to our FAQ on web for more detail. 
      http://www.icpdas.com/faq/7188e/hardware/003.htm
    • Firmware modifiable 
      We provide the Modbus SDK allowing users to develop their custom Modbus firmware.
    Modbus SDK ( in C language )

    If the default firmware doesn't totally suit your requirement. You can use Modbus SDK to modify the default firmware to add extra functions. The Modbus SDK has below features:

    • Supports extra user-defined command protocol (TCP/IP) 
      Modbus/TCP protocol supports 2 basic data format (bit and 2-byte integer). It means if clients (or called masters) don't support Modbus/TCP or you need other format data (for example: string of floating value), I-7188Es (with default firmware) cannot communicate with them. Using this feature, you can develop your special command protocol to transfer any format of data.
    • Register based programming method (easy to use) 
      Modbus library supports 4 internal register tables (iMemory_AI, iMemory_AO, iMemory_DI, iMemory_DO), you can use these to store specific information. When Modbus/TCP clients request to I-7188E, Modbus kernel will response information from these 4 tables.
    • Provides user-defined registers 
      The 4 internal register tables are all open to users. You need to assign these tables by yourself.
    • Can Iink to Modbus/TCP slave devices                                                                                                           
      By using function ModbusTCP_Master2Slave(declared in MBTCP_7E.h),the 7188EX-MTCP can link  8 max . Modbus/TCP device.
    • Can link to Modbus/RTU slave devices 
      By using function ModbusMaster2Slave (declared in MBTCP_7E.h), Modbus/RTU devices can be easily integrated to internal registers of I-7188Es. An I-7188E polling every Modbus/RTU devices and put every necessary information to internal registers. Clients only ask the I-7188E to get all information of Modbus/RTU devices. That reduces loading of Clients.
    • Can link to non-Modbus/RTU serial devices 
      Some serial devices don't support Modbus/RTU. We provide functions to let I-7188E -MTCP access serial devices. You can put information to internal registers of it. Thus, the non-Modbus serial devices can also support Modbus/TCP.
    • Supports X boards 
      You can choose one suitable Xboard to add on an I-7188EX to be on board I/Os.
    • Xserver SDK compatible 
      Modbus SDK is based on Xserver SDK. To lear more programming skills, you can refer demos of Xserver. To get information of demos of Xserver, please refer to CD:\Napdso\7188e\TCP\Xserver\Xserver.htm

     

    Modbus Utility

    We provide Modbus tools for Windows 98/SE/NT/2K/XP, it includes:

    1. Modbus Utility
      • On-line configuration via Ethernet
      • On-line help
      • Automatically generate register mapping tables
      • Configuration export/imp
    2. MBRTU 
      Modbus/RTU client (with source code in VB6) to diagnostic Modbus/RTU slave devices.
    3. MBTCP 
      Modbus/TCP client (with source code in VB6) to diagnostic Modbus/TCP slave devices
    • Basic application 1: protocol converter

    An I-7188E -MTCP runs a default firmware to become a single Modbus/TCP to multi-Modbus/RTU converter. You can simply use the Modbus Utility to configure the device and then set connection between SCADA , HMI software and the I-7188E.
    • Basic application 2: protocol converter with VxComm technique

    An I-7188E -MTCP is also be able to link to serial devices that don't support Modbus/RTU. To use this function, you will need to install VxComm driver on host PCs. After installation, you will be able to access the remote COM ports via the standard serial driver.
    • Advanced application 1: Modbus/TCP controller

    Using the Modbus SDK, users can develop their own custom Modbus firmware, allowing extra functions, integration of serial devices and a Xboard to the Modbus/TCP kernel. Thus an I-7188E can become a powerful controller.
    • Advanced application 2: Modbus/TCP controller with VxComm technique

    When an I-7188E -MTCP links same hardware devices as Advanced application 1 link to, if any devices connected to certain COM ports are not integrated into your custom firmware, you are still able to access the COM ports via the standard serial driver. In order to do this, you must install the VxComm driver on the host PCs

     

    CPU
    CPU 80188, 40MHz or compatible
    SRAM

    512K bytes

    Flash Memory 512K bytes
    EEPROM 2K Bytes
    NVRAM 31 Bytes (battery backup, data valid up to 10 year)
    RTC (Real Time Clock) Yes
    64-bit Hardware Serial Number Yes
    Built-in Watchdog Timer Yes
    Communication Interface
    COM1 RS-232 (TXD, RXD, RTS, CTS, GND)
    COM2 RS-485 (D2+, D2-)
    Ethernet Port 10BASE-T NE2000 compatible Ethernet Controller
    COM Port Formats
    Data bit 7, 8
    Parity Even, Odd, None
    Stop bit 1
    LED Display
    5-Digit 7 Segment LED Display Yes (for I-7188EXD-MTCP only)
    System LED Indicator Yes
    Hardware Expansion
    I/O expansion bus Yes
    User defined I/O pins 14 pins
    Dimensions
    I-7188EX(D)-MTCP 123mm x 72mm x 33mm
    Operating Environment
    Operating Temperature -25°C to +75°C
    Storage Temperature -40°C to +80°C
    Power
    Protection Power reverse polarity protection
    Required Supply Voltage +10 to +30V/DC (non-regulated)
    Power consumption 2W for I-7188EX-MTCP
    3W for I-7188EXD-MTCP

     

    I-7188EX-MTCP I-7188EX with default Modbus/TCP firmware
    I-7188EXD-MTCP I-7188EXD with default Modbus/TCP firmware
    I-7188EXD-MTCP-G I-7188EXD with default Modbus/TCP firmware (Gray Cover)
    I-7188EX-MTCP CR I-7188EX with default Modbus/TCP firmware (RoHS)
    I-7188EXD-MTCP CR I-7188EXD with default Modbus/TCP firmware (RoHS)
    I-7188EXD-MTCP-G CR I-7188EXD with default Modbus/TCP firmware (Gray Cover) (RoHS)
     
     
    Note1: 
    The Modbus firmware can only run under 512K SRAM hardware. If you need more COM ports, you can buy an X board to expand the COM port number. Usage: 
    Step1. Open the cover of the I-7188EX or I-7188EXD. 
    Step2. Plug the X board to the I-7188EX or I-7188EXD. 
    Step3. Close the cover.

     

      s!nus-elektrotechnikai bt.

      Industrial IT & Automation

     

    23 éves jubileum / 23 th Anniversary

     www.s-e.hu    #    www. icpdas.hu

    Email: info@s-e.hu    #   Tel:  96/525530    #    Fax: 96/525531    #    Mobil: 30/9464608 

     

    RS-232, RS-422, RS-485 konverterek, Ethernet konverterek, RS-485 I/O, Modus I/O, Soros-Ethernet konverterek, USB I/O, Ethernet I/O, Profibus, M-bus, Rádió modem, Ethernet switch, CAN, CANopen, DeviceNet, Profinet, HART, BACnet, EtherCAT, EtherNet/IP, Wireless MBus, DALI, ZigBee, LoRaWan, SIGFOX, IoT, TouchPAD  Fogyasztásmérés és leolvasás  USB konverter  ICP DAS HUNGARY

    RS-232 - WiFi konverter, RS-485 - WiFi konverter,

    ICP CON konverter    USR IOT konverter

     

    Sinus-Elektrotechnikai Bt.   ICP DAS HUNGARY

    RS-232 konverter, RS-422 konverter, RS-485 konverter, RS-485 repeater, USB konverter, Soros Ethernet konverter, RS-232 Ethernet konverter, RS-422 Ethernet konverter, RS-485 Ethernet konverter, Ipari Ethernet switch, Managed DIN switch, PAC, PLC, HMI, Programozó kábel, Ipari monitor, Ipari éritőképernyős monitor, Ipari PC, Ipari laptop, Ipari tablet, Ipari panel PC,  Barebone PC, Mini ITX PC, RS-485 I/O, Profibus I/O modul, Profibus gateway, Profibus konverter, Profibus átjáró, Profibus csatlakozó, Modbus I/O, Ethernet I/O, Modbus gateway, CAN konverter, CAN I/O, CANopen konverter és I/O, DeviceNet konverter és I/O, Hart konverter, Ethernet/IP modul és konverter, BACnet/IP modul és konverter, PROFINET konverter, I/O modul, EtherCAT modul, M-Bus modul, konverter, DALi modul, DALI konverter, PLC programozó kábel, Siemens programozó kábel, WiFi I/O, GSM modem, GPRS modem, SMS küldő, ZigBee konverter, ZigBee I/O, Bluetooth modul, LoRaWAN modul, SIGFOX Modul, IIoT MQTT modul, Média konverter, Touch Pad, Optikai leolvasófej, Analóg, Digitális, Soros PCI kártyák, Épület automatizálás, Ipari tápegység, Ipari kamera, MachineVision, Fogyasztásmérés és elemzés, Földrengés előjelzés, Adatgyűjtés eszközei,  Rezgés elemzés, konverter és repeater, Profibus kábel, Profibus csatlakozó, Soros RS-232 RS-485 WiFi konverter, Ipari Gigabit Ethernet switch, WiFi i/o modul, IEC 1107 mérőleolvasás, Optikai leolvasó fej ICP DAS, ICPDAS, ICP CON, MOXA, ADEUNIS, USR IOT, IEI, B+B SmartWorx, ELKO EP, EXSYS, LILLIPUT, STARTECH, PATTON

    All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorisation by any rights holder.

     

    © 2018-2020  Sinus-Elektrotechnikai Bt.  Minden jog fenntartva.

    A műszaki adatok és információk előzetes értesítés nélkül megváltozhatnak.