μPAC-5007D # uPAC-5007D/POE Kontroller/768KB/1x Ethernet/1x RS-232/1x RS-485/LED/ISAGRAF, ICP DAS, ICP CON

Rendelésre 10-15 munkanap
Raktárkészlet: NINCS
μPAC-5007D # uPAC-5007D/POE Kontroller/768KB/1x Ethernet/1x RS-232/1x RS-485/LED/ISAGRAF, ICP DAS, ICP CON
  • μPAC-5007D # uPAC-5007D/POE Kontroller/768KB/1x Ethernet/1x RS-232/1x RS-485/LED/ISAGRAF, ICP DAS, ICP CON
134 714 Ft 171 087 Ft
  • μPAC-5007D # uPAC-5007D/POE Kontroller/768KB/1x Ethernet/1x RS-232/1x RS-485/LED/ISAGRAF, ICP DAS, ICP CON
  • μPAC-5007D # uPAC-5007D/POE Controller/768KB/1x Ethernet/1x RS-232/1x RS-485/LED/ISAGRAF, ICP DAS, ICP CON
  • 80186, 80 MHz CPU
  • MiniOS7 operációs rendszer
  • Fejlesztő szoftver: ISaGRAF Ver.3
  • Különböző tárhelyek:
    512 KB Flash
    16 KB EEPROM
    512 KB Battery Backup SRAM
  • Különböző kommunikációs interfészek (típusfüggő):
    10/100 Base-TX Ethernet
    RS-232/485
    GPS
    2G (GPRS) / 3G (WCDMA)
  • 64-bites hardveres szériaszám
  • I/O bővítési lehetőség
  • Redundáns tápfeszültség bemenet
  • Működési hőmérséklet: -25 ~ +75 °C
  • The ISaGRAF μPAC-5000 series (μPAC-5xx7, μPAC-5xx7D) is an enhanced version of palm-size μPAC. It provides ISaGRAF workbench for PLC user. Owing to the bigger and special form factor design, the μPAC-5xx7(D) can add an internal wireless module, such as 2G, 3G, ZigBee, Wi-Fi, GPS for different wireless application. The optional I/O expansion board, XW-board, is two times larger than the X-board of μPAC-7186 and provides high-protection I/O. 

    For hardware expansion, it also supports an I/O expansion bus. The I/O expansion bus can be used to implement various I/O functions such as DI, DO, A/D, D/A, Timer/Counter, UART, and other I/O functions. Nearly all kinds of I/O functions can be implemented by this bus. But the bus can support only one board. There are more than 10 boards available for μPAC-5xx7(D) series, you can choose one of them to expand hardware features.

     

    MiniOS7 Embedded Operating System (DOS-like)
    Embedded ISaGRAF Ver.3 SoftLogic
    Support IEC 61131-3 Standard
    Accepts max. 64 KB ISaGRAF code size

     

    Model μPAC-5007(D) μPAC-5107(D) μPAC-5207(D) μPAC-5307(D)
    CPU 80186, 80 MHz
    SRAM 768 KB
    Memory Expansion 512 KB Battery Backup SRAM
    Ethernet Port 10/100 Base-TX
    - Yes - -
    - - Yes -
    - - - Yes
    RS-232/485 1/1

     

     

    Models μPAC-5007(D) μPAC-5107(D) μPAC-5207(D) μPAC-5307(D)
    System Software
    OS MiniOS7 (DOS-like embedded operating system)
    Development Software
    ISaGRAF
    Software
    ISaGRAF Ver. 3 IEC 61131-3 standard
    Languages LD, ST, FBD, SFC, IL & FC
    Max. Code Size 64 KB
    Scan Time 2 ~ 25 ms for normal program; 
    10 ~ 125 ms (or more) for complex or large program
    CPU Module
    CPU 80186, 80 MHz
    SRAM 768 KB
    Flash 512 KB
    microSD Expansion Yes (but ISaGRAF doesn't support)
    Battery Backup SRAM 512 KB ; data valid up to 5 years (for retain variables)
    EEPROM 16 KB
    NVRAM 31 Bytes (battery backup, data valid up to 10 year)
    RTC (Real Time Clock) Provide second, minute, hour, date, day of week, month, year
    64-bit Hardware Serial Number Yes, for Software Copy Protection
    Watchdog Timers Yes (0.8 second)
    Communication Ports
    Ethernet RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators)
    COM 1 RS-232 (TxD, RxD, RTS, CTS, GND), non-isolated, Speed: 115200 bps max.
    COM 2 RS-485 (Data+, Data-) with internal self-tuner ASIC; non-isolated, 
    Speed: 115200 bps max.
    LED Indicator
    Programmable LED Indicators 2
    LED Display 5-digit 7-segment LED display for (D) versions
    Hardware Expansion
    I/O Expansion Bus Yes (for one XW-Board only)
    Mechanical
    Dimensions (W x H x D) 91 mm x 123 mm x 52 mm
    Installation DIN-Rail Mounting
    Environmental
    Operating Temperature -25 ~ +75°C
    Storage Temperature -30 ~ +80°C
    Ambient Relative Humidity 10 ~ 90% RH (non-condensing)
    Power
    Input Range  +12 ~ +48 VDC
    Isolation -
    Redundant Power Inputs Yes
    Protection Power reverse polarity protection
    Frame Ground Yes (for ESD Protection)
    Power Consumption 2 W; 2.5 W for (D) version
    Wireless
    Wireless Communication - GPS 2G (GPRS) 3G (WCDMA)
    GPS: μPAC-5107(D)
    Channels 32 (all-in-view tracking)
    Sensitivity -159 dBm
    Acquisition Rate Cold start: 42 seconds; 
    warm start: 35 seconds; 
    reacquisition rate: 0.1 second
    Accuracy Position: 25 m CEP (S/A off); 
    Velocity: 0.1 second (S/A off); 
    Time: ±1 ms
    Protocol NMEA
    2G (GPRS): μPAC-5207(D)
    Band 850/900/1800/1900 MHz
    GPRS Multi-slot Class 10/8
    GPRS Mobile Station Class B
    GPRS Class 10 Max. 85.6 kbps
    CSD Up to 14.4 kbps
    Compliant to GSM phase 2/2+ Class 4 (2 W @ 850/900 MHz); 
    Class 1 (1 W @ 1800/1900 MHz)
    Coding Schemes CS 1, CS 2, CS 3, CS 4
    SMS Text and PDU mode
    3G (WCDMA): μPAC-5307(D)
    Band UMTS : 2100/1900/850 MHz
    Data Transfer UMTS / HSDPA / HSUPA 
    Upload: Max. 5.76 Mbps;
    Download: Max. 7.2 Mbps
    Protocols (Note that certain protocols require optional devices)
    NET ID 1 ~ 255, user-assigned by software
    Modbus RTU/ASCII Master Protocol A max. of 2 Ports: COM1, COM2 and COM3 (*). (To connect to other Modbus Slave devices) 
    A max. of Modbus_xxx Function Block amount for 2 ports: 128.
    Modbus RTU Slave Protocol A max. of 2 COM Ports, COM1 and one of (COM2, COM3) (*). 
    (For connecting ISaGRAF, PC/HMI/OPC Server and HMI panels.)
    Modbus TCP/IP Protocol Ethernet port supports Modbus TCP/IP Slave Protocol for connecting ISaGRAF & PC/HMI up to 6 connections.
    User-defined Protocol Custom protocols can be applied at COM1, COM2 and COM3 ~ 8 using Serial communication function blocks. (*)
    Remote I/O One of COM2 or COM3: RS-485 supports I-7000 I/O modules, I-87K base + I-87K Serial I/O boards, or RU-87Pn + I-87K High Profile I/O boards as remote I/O. A max. of 64 I-7000/87K remote I/O modules can connect to one PAC. (*)
    Fbus Built-in COM2 Port to exchange data between ICP DAS's ISaGRAF PACs.
    Ebus Used to exchange data between ICP DAS ISaGRAF Ethernet PACs via the Ethernet port.
    Send Email Provide functions to send email to a max. of 10 receivers with a single attached file via the Ethernet port through internet. The max. of file size is about 488 KB.
    SMS: Short Message Service One of COM1 or COM3 or COM4 (RS-232) (*) can link to a GSM Modem to support SMS. The user can request data/control the controller via a cellular phone. The controller can also send data and alarms to the user’s cellular phone. Optional GSM Modem: GTM-201-RS232 (850/900/1800/1900 GSM/GPRS External Modem)
    Note: μPAC-5207, 5307 has built-in GPRS, no external GSM/GPRS modem required.
    Redundancy Solution Two PACs plug with XW107 in slot0. One is Master, one is Slave. Master handles all inputs & outputs at run time. If Master is damaged (or power off), Slave will take over the control of Bus7000b. If Master is alive from damaged (or power up again), it takes the control of Bus7000b again. The change over time is about 5 seconds. Control data is exchanging via Ebus (if using a cross cable, no require any Ethernet Switch). All I/O should be RS-485 I/O except the status I/O in the slot 0: XW107.
    CAN/CANopen COM1 or COM3~8 can connect to one I-7530 (converter: RS-232 to CAN) to support CAN/CANopen devices and sensors. One iP-8xx7 supports a max. of 3 RS-232 ports to connect a max. of 3 I-7530. (*)(FAQ-086)
    FTP Client  Enable the FTP Client to upload files from the PAC to a remote FTP server on a PC. (FAQ-151)
    Optional I/O Functions  (Refer to the ISaGRAF PAC I/O Selection Guide for I/O Module list)
    PWM Output
    Pulse Width Modulation Output All XW-Board series support PWM output. Max. 8 channels for one controller.
    500 Hz max. for Off = 1 & On = 1 ms Output square wave: Off: 1 ~ 32767 ms, 
    On: 1 ~ 32767 ms
    Counters
    Parallel DI Counter All XW-Board series support DI counter. Max. 8 channels for one controller.
    Counter value: 32-bit 500 Hz max. Min. ON & OFF width must > 1 ms
    Remote DI Counter All remote I-7K/I-87K DI modules support counters. 100 Hz max. value: 0 ~ 65535
    Remote High Speed Counter I-87082: 100 kHz max., 32-bit
    * Note: The COM3 ~ COM8 are located in the optional XW-Board series if it is installed inside the μPAC-5xx7. (Will be available)
    * ISaGRAF FAQ: www.icpdas.com > Support > FAQ > ISaGRAF Soft-Logic PAC
    * ICP DAS recommends using NS-205/NS-208 or RS-405/408 (Ring Switch) Industrial Ethernet Switches.

     

     


     

      s!nus-elektrotechnikai bt.

      Industrial IT & Automation

     

    23 éves jubileum / 23 th Anniversary

     www.s-e.hu    #    www. icpdas.hu

    Email: info@s-e.hu    #   Tel:  96/525530    #    Fax: 96/525531    #    Mobil: 30/9464608 

     

    RS-232, RS-422, RS-485 konverterek, Ethernet konverterek, RS-485 I/O, Modus I/O, Soros-Ethernet konverterek, USB I/O, Ethernet I/O, Profibus, M-bus, Rádió modem, Ethernet switch, CAN, CANopen, DeviceNet, Profinet, HART, BACnet, EtherCAT, EtherNet/IP, Wireless MBus, DALI, ZigBee, LoRaWan, SIGFOX, IoT, TouchPAD  Fogyasztásmérés és leolvasás  USB konverter  ICP DAS HUNGARY

    RS-232 - WiFi konverter, RS-485 - WiFi konverter,

    ICP CON konverter    USR IOT konverter

     

    Sinus-Elektrotechnikai Bt.   ICP DAS HUNGARY

    RS-232 konverter, RS-422 konverter, RS-485 konverter, RS-485 repeater, USB konverter, Soros Ethernet konverter, RS-232 Ethernet konverter, RS-422 Ethernet konverter, RS-485 Ethernet konverter, Ipari Ethernet switch, Managed DIN switch, PAC, PLC, HMI, Programozó kábel, Ipari monitor, Ipari éritőképernyős monitor, Ipari PC, Ipari laptop, Ipari tablet, Ipari panel PC,  Barebone PC, Mini ITX PC, RS-485 I/O, Profibus I/O modul, Profibus gateway, Profibus konverter, Profibus átjáró, Profibus csatlakozó, Modbus I/O, Ethernet I/O, Modbus gateway, CAN konverter, CAN I/O, CANopen konverter és I/O, DeviceNet konverter és I/O, Hart konverter, Ethernet/IP modul és konverter, BACnet/IP modul és konverter, PROFINET konverter, I/O modul, EtherCAT modul, M-Bus modul, konverter, DALi modul, DALI konverter, PLC programozó kábel, Siemens programozó kábel, WiFi I/O, GSM modem, GPRS modem, SMS küldő, ZigBee konverter, ZigBee I/O, Bluetooth modul, LoRaWAN modul, SIGFOX Modul, IIoT MQTT modul, Média konverter, Touch Pad, Optikai leolvasófej, Analóg, Digitális, Soros PCI kártyák, Épület automatizálás, Ipari tápegység, Ipari kamera, MachineVision, Fogyasztásmérés és elemzés, Földrengés előjelzés, Adatgyűjtés eszközei,  Rezgés elemzés, konverter és repeater, Profibus kábel, Profibus csatlakozó, Soros RS-232 RS-485 WiFi konverter, Ipari Gigabit Ethernet switch, WiFi i/o modul, IEC 1107 mérőleolvasás, Optikai leolvasó fej ICP DAS, ICPDAS, ICP CON, MOXA, ADEUNIS, USR IOT, IEI, B+B SmartWorx, ELKO EP, EXSYS, LILLIPUT, STARTECH, PATTON

    All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorisation by any rights holder.

     

    © 2018-2020  Sinus-Elektrotechnikai Bt.  Minden jog fenntartva.

    A műszaki adatok és információk előzetes értesítés nélkül megváltozhatnak.